POINT3-BINARY64 is a 3-dimensional point made of three IEEE 754 binary64 components in the order (x, y, z).
Layout
- Code: Value
VALUE-ISSUER-2WORD(0x09DL), Issuer0x00000002ADHOC, codec number0x0000050B. Family NUMERIC.
TAG WORD 0x09DE (0000 1001 1101 1110) LLLL=1110
Length ext. TAG 1 WORD 0x0012 (18 WORD in total)
Issuer 2 WORD 0x00000002 (ADHOC)
Codec number 2 WORD 0x0000050B
Payload: [x binary64: 4 WORD][y binary64: 4 WORD][z binary64: 4 WORD]
Interpretation rules
- Each component is read from the most significant WORD first, and the NaN payload and signed zero bit pattern are preserved.
- The CRS and the meaning, order, and unit of the axes are external context. There is no ABI padding.
Validity
- The Payload is exactly 12 WORD, and each 4 WORD span is binary64 interchange bits.
Standards basis and formal status
- The
x, y, zcoordinate order of the point refers to the Point/WKB axis order of the OGC GeoPackage Encoding Standard, and each component follows IEEE 754 binary64. - This Payload is a GEUL compact profile that carries no WKB type/byte-order header or GeoPackage header, and it is not the OGC WKB wire format. The CRS and the meaning and unit of the axes are external context.
Length
- The total is exactly 18 WORD: TAG 1 WORD, Length extension TAG 1 WORD, Issuer 2 WORD, codec number 2 WORD, and Payload 12 WORD, and it uses
LLLL=1110. There is no descriptor and no padding. - If the Payload is not exactly 12 WORD, it is rejected.
Example
- If the three binary64 values in the Payload are
1.0, 2.0, 3.0, the point is(1.0, 2.0, 3.0).